How often does the TEAM5 software collect ESD transactions from each SmartLog?

Article ID: 79704  

Question
How often does the TEAM5 software collect ESD transactions from each SmartLog?

Answer

TEAM5 continuously polls the ESD transactions off each SmartLog device it is communicating with.  For the SmartLog V5, it is estimated that the polling cycle for 1 is approximately 5 seconds. Each SmartLog V5 added to the software will add an additional 5 seconds.

For the SmartLog Pro®, it is estimated that the polling cycle for 1 is approximately 2 seconds. Each SmartLog Pro® added to the software will add an additional 2 seconds.


Article Details
Views: 3518 Created on: Oct 12, 2016